NDP Air Total+ GLP CE

Airborne disinfectant of surfaces of medical devices.
Our Plus

  • Total discharge through its “one-shot” valve.
  • Elaborated from a synergistic blend (NDP) of active ingredients, with next-generation quaternary ammonium compounds.
  • Broad spectrum biocide and rapid action against bacteria, mycobacteria, fungi and viruses.

 

Further information

Fields of Application

Description

  • NDP Air Total+ GLP CE is a product for the airborne disinfection of surfaces of medical devices.
  • Total discharge through its “one-shot” valve, which permits nebulisation of the content in a single application.
  • Elaborated from a synergistic blend (NDP) of active ingredients, with next-generation quaternary ammonium compounds in combination with adjuvant agents and active extracts of essential oils.
  • Broad spectrum biocide and rapid action against bacteria, mycobacteria, fungi and viruses.
  • Eliminates odours caused by bacterial decomposition.
  • The nebulisation allows the disinfecting formula to reach difficult or non accessible corners by other means, and makes NDP Air Total+ GLP CE suitable for terminal disinfections.
  • Product classified as Medical Device, Class IIa.

Applications

Operating theatres, ambulances, laboratories and clean rooms, outpatient areas, medical and veterinary consultancies, air conditioning systems, transport means, etc.

Product Profile

Class IIa Medical Device

Instructions for use

  1. Place the bottle on a smooth surface, and unseal it.
  2. Press and turn the total-discharge valve allowing the product to disperse into the room space. The product forms a cloud that covers a 40 m3 of volume in 1 minute aprox. For the 50 ml format, and 150 m3 in 3 minutes for the 300 ml format.
  3. Once the environment is impregnated, let it act.
  4. The security time is at least 1 hour. Ventilate the room before re-entering.

Certificates / Norms

0476

Product data

Composition:

0,46% Didecyl dimethyl ammonium chloride 70%, 0.10% 2-phenoxyethanol, 0.02% Cinnamaldehyde, 100% Aliphatic solvent, propellant and excipients qsf.



  • State at room temperature: Liquid (actives) – Gas (propellant)
  • Pressure:
    - 20ºC: 4.0 bar
    - 50ºC: 8.0 bar
  • Flammable
  • pH: 6.5 – 8.5
  • Weight:
    - 50ml container: total weight is 45.3 g. Product: 6.0 g; Propellant: 39.3 g.
    - 300ml container: total weight is 255.8 g. Product: 36.0 g; Propellant: 219.8 g.
  • Interaction with materials: The product is not corrosive and do not alter tested materials: AISI 316 stainless steel, aluminum, PMAA-methacrylates.
  • Product sedimentation does not stain surfaces.

Special advice

  • Read the label carefully before using the product. An inadequate use of the product can cause deficient surface disinfection.
  • Maintain temperatures higher than 0 ºC. Avoid freezing.
  • Bottle under pressure. Avoid exposure to sun light and temperatures above 50 ºC. Do not puncture or burn, including after its use. Do not spray on a naked flame or an incandescent body. Keep away from any source of ignition – no smoking.
  • Do not use in combination with products that contain or release chlorine (hypochlorite). Do not use with anionic detergents
  • Due to the materials of the containers, the 50ml container (aluminum container) can be used in MRI rooms (Magnetic Resonance). Do not use with the 300ml container (tin).
  • Hazard statements: Causes serious eye irritation (H319), May cause drowsiness or dizziness (H336). Harmful to aquatic life with long lasting effects (H412). Extremely flammable aerosol (H222). Pressurised container: May burst if heated (H229).
  • Precautionary statements: Avoid breathing vapours (P261). Wear protective gloves/protective clothing/eye protection/face protection. Wash with the hands thoroughly after handling (P280 + P264). Do not spray on an open flame or other ignition source (P211). Do not pierce or burn, even after use (P251). Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking (P210). IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing (P305 + P351 + P338). If eye irritation persists: Get medical advice/attention (P337 + P313). Store in a well-ventilated place. Keep container tightly closed (P403 + P233). Protect from sunlight. Do no expose to temperatures exceeding 50 oC/122oF (P410 + P412). Avoid release to the environment (P273). Dispose of contents and/or container in accordance with dangerous residues regulations (P501).

Important notice

This site is intended for healthcare professionals. By entering this site, you are confirming that you are a healthcare professional.

Data protection notice

We use analysis methods (e.g. cookies) to measure how often our website is visited and how it is used. We also use cookies to link your page visits and website usage with your customer data stored in our CRM system in order to be able to address you individually, i.e. based on your interests and usage. We alsowe embed third-party content from other providers (e.g. videos). We have no influence on further data processing and any tracking by the third-party provider.In this context, we also use service providers in third countries outside the EU that may not guarantee an adequate level of data protection, which entails the following risks Access by authorities without informing the data subject, no data subject rights, no legal remedies, loss of control.By hiring us, you consent to the processes described above. You can revoke your consent with effect for the future. You can find more information in our privacy policy