Use disinfectants safely. Always read the label and product information before use. To prepare the desired working solution, the required amount of water is first set ready. The double bottle is then completely emptied into the water. In doing so, it must be ensured that the concentrated components are not brought into contact. To obtain a 2% working solution, the entire content of a double bottle is dosed per 4 l of water -calculated on the basis of the base component. The lifetime of the prepared terralin® PAA working solution is max. 24 hours. The components base and additive always have to be used together! terralin® PAA is not suitable for chrome plated surfaces and surfaces made of brass or copper. Please refer to manufacturer's instructions regarding the surfaces to be treated and, if necessary, test the material compatibility before application. Do not exceed concentration. The microbiological efficacy and the application properties of peracetic acid are significantly dependent on the pH value of the stock solution. Generally, the recommended concentrations and contact times should not be exceeded with all cleaners and disinfectants, in order to obtain the best possible compatibility of materials. Thus, a peracetic acid solution, as it is also available on the market, has a wide and fast microbiological efficacy, but is not compatible with certain plastics or metals, especially regarding brass and chromium plating. Pitting corrosion, among others, is possible in several stainless steel grades. Using a harmonised 2-component formulation has made it possible to guarantee a very comprehensive effect spectrum with an extraordinarily good and practice-oriented compatibility of materials. terralin® PAA component base contains an active, stabilised, balanced peracetic acid. In addition to an alkaline component to adjust the pH value, the component additive provides phosphates and other anti-corrosion components. During the production of the stock solution by dilution with water and simultaneous mixing of the two components, an almost neutral, buffered application solution with a pH value of approx. 6 is obtained. Ensure complete wetting of the surfaces. Ensure that all visible dirt is removed before disinfection. After completing the work within the desired contact time,, dispose of the working solution and rinse the equipment thoroughly with water. For professional use only. Any serious incidents related to the product are to be reported to the manufacturer and competent authority.
RKI-listed according to German law (§18 IfSG) - scope AB in accordance with DVV/RKI guideline 8% (80ml/l) in 60 minutes.
| Efficacy | Test method | Test Condition | 1 % | 2 % |
|---|---|---|---|---|
| Bacteria, Yeast and Mycobacteria | ||||
| bactericidal | in accordance with VAH | clean conditions | 5 min. / 20 °C | |
| bactericidal | in accordance with VAH | dirty conditions | 5 min. / 20 °C | |
| bactericidal | EN 13727; EN 16615 | clean conditions | 5 min. / 20 °C | |
| bactericidal | EN 13727; EN 16615 | dirty conditions | 5 min. / 20 °C | |
| yeasticidal | in accordance with VAH | clean conditions | 5 min. / 20 °C | |
| yeasticidal | in accordance with VAH | dirty conditions | 5 min. / 20 °C | |
| yeasticidal | EN 13624; EN 16615 | clean conditions | 5 min. / 20 °C | |
| yeasticidal | EN 13624; EN 16615 | dirty conditions | 5 min. / 20 °C | |
| mycobactericidal | EN 14348 | clean conditions | 5 min. / 20 °C | |
| mycobactericidal | EN 14348 | dirty conditions | 5 min. / 20 °C | |
| tuberculocidal | EN 14348 | clean conditions | 5 min. / 20 °C | |
| tuberculocidal | EN 14348 | dirty conditions | 5 min. / 20 °C | |
| Virus | ||||
| virucidal activity | EN 16777 | clean conditions | 5 min. / 20 °C | |
| virucidal activity | EN 14476 | clean conditions | 30 min. / 20 °C | |
| Bacterial spores | ||||
| sporicidal | EN 17126 | clean conditions | 10 min. / 20 °C | |
| sporicidal (C. difficile) | EN 17126; EN 17846 | clean conditions | 10 min. / 20 °C | |
| sporicidal (C. difficile) | EN 17126; EN 17846 | dirty conditions | 60 min. / 20 °C | |
Composition:
terralin PAA base:
100 g of solution contains: 5,4 g peracetic acid; other: hydrogenperoxide and acetic acid.
terralin PAA additive:
potassium hydroxide, corrosion inhibitors, phosphates
Chemical-physical data
terralin PAA base
density: 1.1 g/cm3, 20 °C
Colour: colourless
Flash point: 94 °C
Form: liquid
pH value: 2,28 (10ml/l)
terralin PAA additive
density: approx. 1.18 g/cm3, 20 °C
Colour: yellow
Flash point: not applicable
Form: liquid
pH value: 12,3 (10ml/l)
<5% non-ionic surfactants
Ensure that all visible dirt is removed before disinfection. Wearing protective gloves is absolutely necessary. Store always upright. Do not seal the container gas tight. Protect from direct sunlight and heat. Keep away from heat and sources of ignition. For further information on safe handling and storage conditions, please refer to the safety data sheet.
| Item | Delivery form | Item no. |
|---|---|---|
| terralin® PAA 2x80 ml, 160 ml bottle | 12 / carton(s) | on request |
schülke manufactures its products using advanced and safe production processes while maintaining high quality standards.