Wipe surfaces thoroughly with the impregnated cloth. Make sure that it is completely wetted and let it soak in. Make sure that all visible dirt is removed with dry disposable wipes or the mikrozid® sensitive wipes before disinfection and that the lid is tightly closed again after use. Pay attention to hygienic aspects during opening. The wiping range depends on the room temperature and the structure of the surface to be disinfected. Only treat small areas. Please note the reprocessing recommendations of the medical device manufacturers. After the final disinfection of semicritical A medical devices, wiping with water of suitable quality is required. Avoid recontamination. More information available on request. Serious incidents related to the product must be reported to the manufacturer and the competent authority.
| Efficacy | Test method | presetSubheadlineEffTestCond | ready-to-use |
|---|---|---|---|
| Bacterial spores | |||
| sporicidal | EN 17126 | dirty conditions | 30 min. |
| sporicidal (C. difficile) | EN 17126; EN 17846 | dirty conditions | 5 min. |
| sporicidal (C. difficile) | in accordance with VAH | dirty conditions | 5 min. |
| Bacteria, yeasts and mycobacteria | |||
| bactericidal | EN 13727; EN 16615 | dirty conditions | 1 min. |
| bactericidal | EN 14561 | dirty conditions | 1 min. |
| mycobactericidal | EN 16615 (mod.) | dirty conditions | 5 min. |
| mycobactericidal | EN 14348; EN 14563 | dirty conditions | 5 min. |
| tuberculocidal | EN 14348; EN 14563 | dirty conditions | 5 min. |
| tuberculocidal | EN 16615 (mod.) | dirty conditions | 5 min. |
| yeasticidal | EN 13624; EN 14562 | dirty conditions | 1 min. |
| yeasticidal | EN 16615 | dirty conditions | 1 min. |
| Fungi and spores | |||
| fungicidal | EN 13624; EN 14562 | dirty conditions | 5 min. |
| fungicidal | EN 16615 (mod.) | dirty conditions | 5 min. |
| Viruses | |||
| limited spectrum virucidal activity | EN 16777 | dirty conditions | 5 min. |
| limited spectrum virucidal activity | EN 14476; EN 17111 | dirty conditions | 5 min. |
| limited spectrum virucidal activity | EN 16615 (mod.) | dirty conditions | 5 min. |
| limited spectrum virucidal activity | in accordance with DVV/RKI guideline | 5 min. | |
| Simian virus 40 (Polyoma SV40) | in accordance with DVV/RKI guideline | dirty conditions | 1 min. |
| Simian virus 40 (Polyoma SV40) | EN 16615 (mod.) | dirty conditions | 1 min. |
| virucidal activity | EN 16615 (mod.) | dirty conditions | 5 min. |
| virucidal activity | EN 14476; EN 16777 | dirty conditions | 5 min. |
| virucidal activity | EN 17111 | dirty conditions | 5 min. |
| virucidal activity | in accordance with DVV/RKI guideline | 5 min. | |
0.06 % peracetic acid
Other components: hydrogen peroxide, acetic acid
Wearing protective gloves (e.g. made of nitrile rubber) is absolutely necessary.
Do not use on aluminum and non-ferrous metals and do not mix with other cleaning agents.
schülke guarantees a shelf life of 28 days after opening the packaging and following the instructions.
For professional use only.
| Item | Delivery form | Item no. | GTIN |
|---|---|---|---|
| mikrozid PAA+ wipes 50 ST DS | 10 / carton(s) | 70004144 | 4032651987351 |
schülke manufactures its products using advanced and safe production processes while maintaining high quality standards.